Products
Semi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit
  • Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit

Semi-hermetic Single-Stage Screw Refrigeration Compressor Unit

Lynxcool manufactures Semi-hermetic Single-Stage Screw Refrigeration Compressor Units designed for industrial refrigeration systems requiring stable operation, high efficiency, and flexible capacity control. The unit combines a self-developed 5/6 asymmetric rotor profile, integrated motor protection, efficient oil management, and intelligent monitoring functions to provide reliable cooling performance for cold storage, food processing, industrial process cooling, heat pump systems, and commercial HVAC applications.

This semi-hermetic single-stage screw refrigeration compressor unit features a semi-hermetic design, integrating the motor and screw mechanism within a single sealed housing. This reduces the risk of refrigerant leakage and enhances system reliability. Its compact design simplifies installation and maintenance, making it particularly suitable for refrigeration systems with stringent requirements regarding space constraints, energy consumption, and long-term operational stability.

Specification

Parameter Specification
Product Type Semi-hermetic Single-Stage Screw Refrigeration Compressor Unit
Refrigerant R717 Ammonia / R22 / R404A / R507A / R744 / R290 / R1270
Cooling Temperature Range -55℃ to +20℃
Capacity Range Available for medium and large industrial refrigeration systems
Frequency 50Hz / 60Hz
Motor Voltage 400V/3/50Hz - 460V/3/60Hz
Capacity Control Step control and variable capacity adjustment
Applications Cold storage, food processing, chemical industry, industrial cooling, heat pumps

Technical Features and Advantages

Self-developed 5/6 Asymmetric Rotor Profile

The Semi-hermetic Single-Stage Screw Refrigeration Compressor Unit uses Lynxcool’s proprietary 5/6 rotor design, optimizing the meshing process between male and female rotors. The improved rotor geometry reduces internal leakage, mechanical vibration, and compression loss, helping the compressor maintain stable efficiency during continuous operation.

Integrated Semi-hermetic Structure

The compressor adopts an integrated motor and compression chamber design. This structure reduces external connection points, minimizes refrigerant leakage risks, and provides better protection for internal components in demanding industrial environments.

The compact housing integrates key components including suction filters, shut-off valves, temperature sensors, and protection devices, reducing installation space requirements and simplifying system layout.

High-efficiency Oil Separation System

A multi-stage oil separation system is installed inside the compressor unit to improve oil recovery efficiency. Efficient oil management reduces oil circulation into the refrigeration system, helping maintain clean heat exchangers and stable heat transfer performance.

The optimized oil return design supports long-term operation under low-temperature and heavy-load conditions.

Advanced Motor Protection and Monitoring

The built-in motor protection module continuously monitors operating conditions, including:

  • Motor overheating
  • Phase loss
  • Phase sequence error
  • Abnormal operating conditions

The intelligent control system provides real-time operation feedback, allowing operators to monitor compressor status and improve maintenance efficiency.

Multi-bearing Rotor Support System

The compressor adopts a precision multi-bearing structure to support rotor operation under high load conditions. The optimized bearing arrangement reduces axial and radial movement, improving operating stability and extending service life.

Flexible Capacity Regulation

The unit supports adjustable capacity control to match different cooling demands. The step-less regulation system allows the compressor to operate efficiently under partial-load conditions, reducing unnecessary energy consumption during seasonal or variable refrigeration loads.

Low-temperature Refrigeration Capability

The Semi-hermetic Single-Stage Screw Refrigeration Compressor Unit is designed for low and medium-temperature applications with evaporating temperatures down to -55℃.

It is suitable for:

  • Frozen food storage
  • Blast freezing systems
  • Cold chain warehouses
  • Industrial process cooling

Flexible Installation Design

The suction and discharge shut-off valves support flexible installation layouts. The adjustable piping connection design helps engineers optimize machine room space utilization and simplify system integration.

Product Technical Specifications

The following tables summarize the technical specifications of Lynxcool’s Semi-hermetic Single-Stage Screw Refrigeration Compressor Unit:


model Lynx

 

 

071

081

091

101

110

120

140

discharge rate 50/60[Hz]

 

m³/h

270/324

307/368

344/413

380/456

413/496

480/576

560/672

weight

 

Kg

510

518

532

538

660

670

680

Oil filling volume

 

dm³

11

11

11

11

17

17

17

oil heater

 

 

200W-230V-50/60Hz

Inner diameter of exhaust sleeve/tube /take over size

 

mm/ inch

54.1/ 2-1/8"

54.1/ 2-1/8"

54.1/ 2-1/8"

67/ 2-5/8"

80/ 3-1/8"

80/ 3-1/8"

80/ 3-1/8"

Intra-lumen diameter of the suction (sheath)Ø/take over size

 

mm/ inch

80/ 3-1/8"

80/ 3-1/8"

92.5/ 3-5/8"

92.5/ 3-5/8"

105.5/ 4-1/8”

105.5/ 4-1/8"

105.5/ 4-1/8"

energy management

 

 

134-S: Stepwise: Full load, 75%,50%, Minimum. (Non-stepwise: Full load... Minimum, or Full load... 50% as required)

Motor protection module

 

 

INT69 SNY

lube

 

 

SO02 (except Vi=2.2), S003 (Vi=2.2)

Standard motor¹)

 

 

400V/3/50Hz-460V/3/60Hz

134-S-W

starting current

LRAY

A

138

159

193

254

224

280

280

LRA△

A

422

459

580

770

693

842

842

Maximum operating current

FLA

A

107

111

123

131

156

174

199

134-S/134-5-L

starting current

LRAY

A

159

193

254

254

318

361

361

LRA△

A

459

580

770

770

953

1095

1095

Maximum operating current

FLAL

A

118

132

148

156

182

202

228

134-S-R

starting current

RAY

A

-

254

254

1

361

403

403

LRA△

A

-

770

770

-

1095

1208

1208

Maximum operating current

FLA

A

-

142

160

1

203

230

263

 

Model 134-S

 

 

160

180

210

220

240

270

300

discharge rate 50/60[Hz]

 

m³/h

640/768

720/864

805/966

850/1020

910/1092

1000/1200

1100/1320

weight

 

Kg

930

940

950

980

1330

1350

1390

Oil filling volume

 

dm³

23

23

23

23

25

25

25

oil heater

 

 

275W-230V-50/60Hz

Inner diameter of exhaust (sheath) tube O/tube size

 

mm/ inch

80.0/ 3-1/8"

80.0/ 3-1/8"

80.0/ 3-1/8"

80.0/ 3-1/8"

105.5/ 4-1/8"

105.5/ 4-1/8"

105.5/ 4-1/8"

Inner diameter of the suction (tube) /take over size

 

mm/ inch

105.5/ 4-1/8"

105.5/ 4-1/8"

105.5/ 4-1/8"

105.5/ 4-1/8"

134.8/0133

134.8/0133

134.8/0133

energy management

 

 

134-S: Stepwise: Full load, 75%,50%, Minimum. (Non-stepwise: Full load... Minimum, or Full load... 50% as required)

Motor protection module

 

 

INT69 SNY

lube

 

 

S002 (except Vi=2.2), S003 (Vi=2.2)

Standard Motor"

 

 

400V/3/50Hz-460V/3/60Hz

134-S-W

starting current

LRAY

A

354

374

453

543

551

703

791

LRA△

A

1064

1155

1333

1645

1667

2109

2390

Maximum operating current

FLA

A

229

254

266

276

330

367

402

134-S/134-5-L

starting current

LRAY

A

374

453

543

595

703

783

876

LRA△

A

1155

1333

1645

1802

2109

2348

2627

Maximum operating current

FLAL

A

260

295

310

335

400

435

490

134-S-R

starting current

RAY

A

453

543

595

1

783

876

1062

LRA△

A

1333

1645

1802

1

2348

2627

3186

Maximum operating current

FLA

A

299

341

366

-

446

501

569

(Additional 160-300 series available for higher refrigeration capacity requirements.)

Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit


Main Applications

Industrial Process Cooling

The compressor unit provides stable cooling performance for industrial processes requiring continuous temperature control, including chemical production, manufacturing plants, and energy-intensive facilities.

Food Processing and Cold Storage

Designed for refrigeration systems in:

  • Meat and seafood processing
  • Frozen food production
  • Cold chain logistics
  • Large cold storage warehouses

The unit supports reliable low-temperature operation for long-term storage and freezing applications.

Industrial Heat Pump Systems

The compressor can be integrated into industrial heat pump systems for heat recovery, process heating, and hot water production.

Commercial and Specialized Air Conditioning

Suitable for large-scale HVAC applications including:

  • Industrial buildings
  • Cleanrooms
  • Hospitals
  • Large commercial facilities

Semi-hermetic Single-Stage Screw Refrigeration Compressor UnitSemi-hermetic Single-Stage Screw Refrigeration Compressor Unit

Why Choose Lynxcool Semi-hermetic Screw Compressor Unit?

Refrigeration Engineering Experience

Lynxcool provides complete refrigeration solutions covering compressor units, cold storage systems, and industrial cooling projects. Our engineering team supports equipment selection, system design, installation guidance, and after-sales service.

Reliable Manufacturing Process

Each Semi-hermetic Single-Stage Screw Refrigeration Compressor Unit undergoes strict quality control during machining, assembly, performance testing, and final inspection to ensure stable operation after delivery.

Customized Refrigeration Solutions

Different industries require different cooling conditions. Lynxcool provides customized compressor configurations according to:

  • Refrigerant type
  • Cooling capacity requirements
  • Temperature range
  • Installation conditions
  • Control system requirements

Semi-hermetic vs Open-type Screw Compressor Unit: How to Choose?

When selecting a screw refrigeration compressor unit, the compressor structure directly affects installation method, maintenance requirements, system reliability, and operating cost.

Lynxcool provides both Semi-hermetic and Open-type Screw Compressor Units for different industrial refrigeration applications. The right choice depends on factors such as refrigerant type, cooling capacity, maintenance conditions, installation environment, and long-term operating requirements.

Comparison Table

Comparison Item Semi-hermetic Single-Stage Screw Compressor Unit Open-type Screw Compressor Unit
Structure Design Motor and screw compressor integrated in a sealed housing Compressor and motor separated with external drive connection
Motor Protection Built-in motor protection with temperature and electrical monitoring External motor protection required according to system design
Installation Space Compact structure, suitable for limited machine room space Requires additional space for motor installation and coupling arrangement
Refrigerant Leakage Risk Lower leakage risk due to integrated sealed design Requires more attention to shaft seal and external connection points
Maintenance Method Easier routine maintenance with integrated components Motor and coupling components can be independently serviced
Energy Efficiency High efficiency for medium and large refrigeration systems with stable load Excellent efficiency for large industrial systems and heavy-duty applications
Capacity Range Suitable for medium and large refrigeration applications Suitable for large-scale industrial refrigeration systems
Noise & Vibration Lower vibration due to integrated motor-compressor structure Depends on motor alignment and coupling design
Installation Flexibility Easier installation for compact refrigeration rooms More flexible for customized industrial layouts
Typical Applications Cold storage, food processing, HVAC, heat pumps, industrial cooling

Six-Step Project Service

System Design

Provide refrigeration system proposals, equipment selection, and technical solutions according to project requirements.

Component Selection and Manufacturing

Select suitable compressor models, valves, controllers, and refrigeration components based on operating conditions.

Production and Quality Inspection

Complete precision machining, assembly, and performance testing before shipment.

Installation Support

Provide installation guidance, commissioning assistance, and technical documentation.

System Optimization

Support operation adjustment to improve efficiency and reduce energy consumption.

After-sales Service

Offer technical consultation, maintenance support, and spare parts assistance throughout the equipment lifecycle.

FAQ

What refrigerants can be used with the Semi-hermetic Single-Stage Screw Refrigeration Compressor Unit?

The unit supports multiple refrigerants including ammonia R717, R22, R404A, R507A, R744, R290, and R1270. The final refrigerant selection depends on system design requirements and application conditions.

What temperature range can this screw compressor unit achieve?

The compressor is designed for industrial refrigeration applications with evaporating temperatures down to approximately -55℃, covering low-temperature freezing and medium-temperature cooling requirements.

What are the advantages of a semi-hermetic screw compressor design?

A semi-hermetic design integrates the motor and compressor into a sealed structure, reducing refrigerant leakage risks, improving protection, and increasing system reliability.

How does the compressor improve energy efficiency?

The optimized rotor profile, efficient oil separation system, and capacity regulation function allow the compressor to maintain higher efficiency under different load conditions.

Is this compressor suitable for cold storage projects?

Yes. It is widely used in cold storage warehouses, food processing plants, frozen food production lines, and cold chain logistics systems.

Can Lynxcool provide customized refrigeration solutions?

Yes. Lynxcool provides equipment selection, system design, manufacturing, installation support, and after-sales service according to project requirements.

Hot Tags: Semi-hermetic Single-Stage Screw Refrigeration Compressor Unit Manufacturer, Supplier, Factory
Send Inquiry
Contact Info
Welcome to send your detailed demands for Refrigeration Compressor Unit, Screw Compressor Unit, Evaporator. Our professional sales team from this China refrigeration manufacturer will reply quickly, provide custom plans and one-stop purchasing service.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.Privacy Policy
RejectAccept